Load cell, Digital Dynamometer & Crane Scale Recalibration

Careful investment and installation of new load cell test machines enables Straightpoint to offer a world class re-calibration and repair service.
Our standard turnaround time for this work is 3-5 working days, although any special issues and considerations may require additional attention.
Straightpoints’ calibration and repair industrial facilities at our UK and USA facilities serve all countries across the world.
They are equipped with a range of load cell calibration test rigs (with closed-loop, servo-controlled testing ability) up to 350te / 770,000lbs.
All types of load cells, dynamometers, crane scales, loadlinks and other force transducers maybe calibrated and certified including Mantracourt, Strainstall, JCM Load Monitoring, Scotload, Dillon, Tractel, Eilon Engineering, Red Rooster, Elite Transducers, Yale and many more – as well as our own brand products.
It is important load systems used to measure and monitor forces across industry are optimised for peak accuracy, providing predictable output to recognised standards.

This email address is being protected from spambots. You need JavaScript enabled to view it.





It is important load systems used to measure and monitor forces across industry are optimised for peak accuracy, providing predictable output to recognised standards.

Industrial calibration test machines

The Straightpoint facilities can apply and exert a wide spectrum of known loads and forces - from just a few kilograms or lbs to many hundreds of tonnes – to test and calibrate load cells and force sensors supplied by clients.
Machines installed at the Straightpoint facility are UKAS ISO 17025 / NIST traceable rigs, Class 0.5 standard and certified by the National Physical Laboratory in London.
For the purposes of industrial calibration our inventory of load cell testing machines is:
250kg / 550lbs dead weight
6.5te / 14,000lbs hydraulic tensile force
6.5te / 14,000lbs hydraulic compressive force
12te / 25,000lbs hydraulic tensile force
2 x 50te / 110,000lbs hydraulic tensile force
50te / 110,000lbs hydraulic compression force
100te / 220,000lbs hydraulic tension and compression
350te / 770,000lbs hydraulic tension and compression

 

When to calibrate load cells, digital dynamometors and other force sensors?

Load cells tend to become unstable or drift for a variety of reasons.
Factors that can adversely affect function include gradual degrading of the load cell, instrumentation fault development, cabling and termination, electrical influence and mechanical effects.
Failure to inspect or clean load cells is a significant factor that can lead to operational, functional and calibration issues.
Particulate matter can build up around load cells and load cell mounts over time, even in clean environments.
Outdoor load systems face more variable-to-extreme conditions. Weigh systems such as crane scales are subject to inclement and seasonal changeable weather, leading to problems developing in previously accurate load cells. A typical problem might be with connected load cell drains that can cause force sensor failure over time.
Calibration technicians in our service department are always available to discuss client requirements and related load cell and force measurement issues.

Important Warning: When a load system fails to function, not delivering any force measurement or monitoring information, do not simply disconnect the system.
An investigation of the full load system is normally required to ensure return to safe and high performance operation. Simple re-calibration of a single faulty load cell within a system may have dangerous effects leading to mechanical failure.

Certified load cell calibration service

Straightpoint offers world class aftersales, care and calibration and is committed to a two-three day turn round, endeavouring to calibrate, certify and despatch equipment to any international location worldwide, within two working days of receipt.

Calibration technicians in our service department are always available to discuss client requirements and related load cell and force measurement issues.

Repair Enquiries
  1. Company
    Invalid Input
  2. Name*
    Please let us know your name.
  3. Country*
    Invalid Input
  4. Email*
    Please let us know your email address.
  5. Tel:*
    Invalid Input
  6. Message*
    Please let us know your message.
  7. How did you find us
    Invalid Input

 

Distributors Worldwide

straightpoint global network

Straightpoint

Hampshire, UK HQStraightpoint offices
Tel: +44(0)2392 484491

Camarillo, CA, USA HQ
Tel: 1-805-246-1462
Houston, TX USA (sales)
Tel: 713-955-2655
Minneapolis, MN USA (sales)
Tel: 612-808-8969

Customer Service Support